Pepperl+Fuchs KFA6-SR2-EX1.W 103374 proximity sensor or switch controls

Артикул: 040E012E
Pepperl+Fuchs KFA6-SR2-EX1.W 103374 proximity sensor or switch controls
Скидка
Pepperl+Fuchs KFA6-SR2-EX1.W 103374 proximity sensor or switch controls
1 1 руб.

Есть в наличии (5000)

Pepperl+Fuchs KFA6-SR2-EX1.W 103374 proximity sensor or switch controls

Pepperl + Fuchs 2 Channel Zener Barrier, ATEX

Pepprl+Fuchs KFA6-SR2-EX2.W (KFA6SR2EX2W)

103373 Pepperl Fuchs — KFA6-SR2-EX2.W

Pepperl+Fuchs KFA6-SR2-Ex1.W Switch Amplifier, 103374

Pepprl+Fuchs KFD2-SR2-EX1.W (KFD2SR2EX1W)

This isolated barrier is used for intrinsic safety applications. It transfers digital signals (NAMUR sensors/mechanical contacts) from a hazardous

area to a safe area.

The proximity sensor or switch controls a form C changeover relay contact for the safe area load. The barrier output changes state when the input

signal changes state. The normal output state can be reversed using switch S1. Switch S3 is used to enable or disable line fault detection of the

field circuit.

During an error condition, relays revert to their de-energized state and LEDs indicate the fault according to NAMUR NE44.

Pepperl+Fuchs Process Automation KFA6-SR2-EX1.W Isolator, Digital, K-System, Switch Amplifier, 1 Channel, 230VAC, 103374

Conductivity switch amplifier KFA6-ER-Ex1.W.LB

1-channel isolated barrier

230 V AC supply

Level sensing input

Adjustable range 1 k and 150 k

Relay contact output

Fault Relay Contact Output

Adjustable time delay up to 10 s

Minimum/Maximum Control

Line fault detection

Function of KFA6-ER-Ex1.W.LB

This isolated barrier is used for intrinsic safety applications. The device generates the AC measuring voltage to the conductive probe.

As soon as the affected Medium to be monitored by the electrodes, the change-over relay contact of the device.

The device is voltage and temperature to stabilize and ensures a defined switching behavior.

The device can be used as on/off control or as a Minimum/ Maximum control. A signal delay can be set in the range between 0.5 s and 10 s.

The device is equipped with a line break monitoring (electricity free Relay in case of error). The line break is indicated by a red LED. By using the line break monitoring the output is used as an error signal output. When disabled, the LB-Monitoring output II follows the output I.

Related products of KFA6-ER-Ex1.W.LB

Matching System Components

K-DUCT-BU

Profile rail

Cable channel in the mounting profile integrated, Safe spatial separation of the Ex and Non-Ex signals, No additional cable guides necessary, standard length 1.8 m, can be shortened, With mounting AIDS

Accessories

KF-ST-5GN

Terminal block

3-pole screw terminal, For KF modules of K-system, packaging unit: 5 pieces, green

KF-ST-5BU

Terminal block

3-pole screw terminal, For KF modules of K-system, packaging unit: 5 pieces, blue

KF-CP

Coding pins

Coding of the K-System-terminal blocks, encoding the LB/FB-System-front sockets, packaging unit: 20 x 6 coding pins

Please contact me get more information

Email:Mia@cwlyautomation.com

VK/Whatsapp/Telegram:+8613667120925

Website: www.cwlyautomation.com



06:56
22
Нашли ошибку?
Пояснение, что не работает, не обязательно


Используя этот сайт, вы соглашаетесь с тем, что мы используем файлы cookie.